Home > Knowledge > Content
A few precautions of using air compressor dryers
- Jan 07, 2019 -

1. Don not exposure Sun, rain, wind or a place with a relative humidity greater than 85%.And do not place it in an atmosphere which is dusty, corrosive or flammable. Do not place in a place where there is vibration or condensation. Do not place it too close to the wall surface to avoid poor ventilation. It must be used in an environment without corrosive gas, and a desiccator with a copper tube or a stainless steel heat exchanger type dryer should be used. It should be used at an ambient temperature of 40 ° C or less.

2.Don not connect the entrance of  the compressed air. In order to repair,

a bypass line should be provided to ensure maintenance space. It is necessary to prevent the vibration of the air compressor from being transmitted to the dryer. The piping weight should not be added directly to the dryer.

3. Do not stand up the drain pipe, do not fold or crush.

4.The fluctuation of the pressure power supply is less than 10 percent. A properly designed leakage circuit breaker should be provided. Must be grounded before use.

5.The temperature of the Compressed air entrance is more than high, the ambient temperature is too high (above 40°C), the flow rate exceeds the rated air volume, the voltage fluctuation exceeds ±10%, the ventilation is too bad (the air is also ventilated in winter, otherwise the room temperature will rise), the protection circuit will play a roll, the indicator light is off, stop running.

6.When the air pressure is more than 0.15MPa, the drain of the normally open automatic drain can be closed. The displacement of the air compressor is too small, the drain port is open, and air is blown out.

7.The quanlity of the compressed air is too bad. If dust or oil mix in,it will attach to the Heat exchanger, then will reduce the Work efficiency.At the same time,the Drainage is also easy to fail. It is desirable to install a filter at the inlet of the dryer and to confirm that the drainage is not less than once a day.

8. The dryer vent will be cleared use the vacuum cleaner every month.

9. Turn on the power, and then turn on the compressed air after the operation is stable. After stopping the operation, you must wait for more than 3 minutes before starting again.

10.If use the automatic drain, should often check the function of the drain whether normal. Always clean the dust on the condenser.And check the pressure of the refrigerant to determine if the refrigerant leaks and if the capacity of the freezer changes. Check to see if the temperature of the condensate is normal.

 

If you want to know more about Air Compressor or Screw Air Compressor Parts, welcome to scan http://www.qdfutai.cn or contact me on Qingdaofutai@qdfutai.cn